Conductor Material
Copper
Material Shape
Round Wire
Range of Application
Overhead Line
Certification
ISO9001, CE, ASTM
Size
Copper Stranded Wire,Copper Conductor,Stranded Cop
Class of Conductor
Class 2 Stranded Conductor
Number of Wires
7,19,37,61,91
APPLICATION
Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications.
Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook up, jumpers, and grounds in
electrical construction. Soft Drawn copper is unilay construction.
CABLE STANDARDS
Enterprise Standards, Chinese National Standard, IEC, BS,ASTM ,AS, DIN and etc. upon request.
The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the JiangNan Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved
Basic Information-(ASTM B2 & B8)
Conductor: Medium Hard-Drawn Stranded Copper Wire
Cross-sectional Area:
AWG=8,6,4,3,2,1,4/0,3/0,2/0,1/0
MCM/Kcmil=250,300,350,500,600,750,1000
Technical Data-(ASTM B2 & B8)
Stranded Class | AA |
Nominal Cross-sectional Area(AWG) | Number of Wires/Diameter of Wires (mils) | Nominal Cross-sectional Area(mm2) | Max.D.C.resistance Of Conductor At 20ºC | Appro.Weight | Tensile Strength min/max | Nominal Elongation,% min |
(lbs/1000ft) | (Ω/km) | (lbs/1000ft) | (Kg/km) | (Mpa) | In 10 in.(250 mm) |
4/0 | 7/173.9 | 107.2 | 0.0500 | 0.164 | 653.1 | 972.0 | 290/340 | 3.8 |
3/0 | 7/154.8 | 85.0 | 0.0630 | 0.207 | 518.1 | 771.1 | 295/345 | 3.6 |
2/0 | 7/137.9 | 67.4 | 0.0795 | 0.261 | 410.9 | 611.5 | 305/350 | 3.2 |
1/0 | 7/122.8 | 53.5 | 0.100 | 0.328 | 325.8 | 484.9 | 310/360 | 3.0 |
Find this product online: www.wxjncable.com | Cables & Accessories
Aerial Cable(Overhead Line) | Bare Conductor | Medium Hard Drawn Copper Stranded Wire(ASTM B2 & B8)
CONSTRUCTION-(ASTM B2 & B8)
Size | Stranding | Stranding Class | Weight | Diameter (mils) | Medium-Hard Drawn |
Individual Wires | Complete Conductor | Rated Strength | DC Resistance @20°C |
(AWG-MCM) | Number of Wires | (lbs/1000 ft) | (lbs) | (ohms/1000 ft) |
STRANDED |
8 | 7 | B | 51 | 49 | 146 | 610 | 0.6629 |
6 | 7 | B | 81 | 61 | 184 | 959 | 0.4169 |
4 | 7 | A, B | 128.9 | 77 | 232 | 1505 | 0.2622 |
3 | 7 | A, B | 162.5 | 87 | 260 | 1885 | 0.2079 |
2 | 7 | A, B | 204.9 | 97 | 292 | 2360 | 0.1650 |
1 | 7 | A | 258.4 | 109 | 328 | 2955 | 0.1309 |
1/0 | 7 | A, AA | 326.1 | 123 | 368 | 3705 | 0.1037 |
2/0 | 7 | A, AA | 410.9 | 138 | 414 | 4640 | 0.08224 |
2/0 | 19 | B | 410.9 | 84 | 418 | 4765 | 0.08224 |
3/0 | 7 | A, AA | 518.1 | 155 | 464 | 5812 | 0.06522 |
4/0 | 7 | A, AA | 653.3 | 174 | 522 | 7278 | 0.05172 |
4/0 | 19 | B | 653.3 | 106 | 528 | 7479 | 0.05172 |
250 | 19 | A | 771.9 | 115 | 574 | 8836 | 0.04378 |
250 | 37 | B | 771.9 | 82 | 575 | 8952 | 0.04378 |
300 | 19 | A | 926.2 | 126 | 628 | 10530 | 0.03648 |
350 | 19 | A | 1080.6 | 136 | 679 | 12200 | 0.03127 |
500 | 37 | A, B | 1543.8 | 116 | 814 | 17550 | 0.02189 |
600 | 37 | A, AA | 1852.5 | 127 | 891 | 21060 | 0.01825 |
750 | 61 | A, B | 2315.6 | 111 | 998 | 26510 | 0.01459 |
1000 | 61 | A, B | 3087.5 | 128 | 1152 | 35100 | 0.01094 |