Conductor Material
Underground
Sheath Material
Industrial
Insulation Material
Power Stati
Material Shape
Round Wire
Certification
ISO9001, CCC
Name
Steel Wire Armoured, PE Sheath LV 3 Core Cable
Transport Package
Steel Drum, Wooden Drum, Steel Wooden Drum
APPLICATION
YJV33-Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
This product is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 0.6/1KV
BASIC INFORMATION
Code Name
YJV33
Rated Voltage (Uo/U)
0.6/1KV
Cable Structure
Copper Conductor/XLPE Insulation/Steel Wire Armoured /PE Sheath
CONSTRUCTION
Conductor
Number of conductors:1,2,3,4,5,3+1,4+1
The conductors shall comply with the requirement given in IEC
Insulation
XLPE(Cross-linked Polyethylene) according to IEC
Sheath
PE(Polyethylene) according to IEC
Armoured
Steel Wire
CABLE STANDARDS
GB/T12706-2008,IEC,BS,ASTM and etc. upon request.
The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the JiangNan Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed.
CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 90ºC
Max.short-circuit temperature
Maximum shall not exceed 250ºC(5s Max,Duration)
Installation temperature
Ambient temperature under installation shall not be below 0ºC
Minimum bending radius
The bending radius of cable: (D-Diameter of cable)
-------------------------------------≥15D
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated PE Sheathed Steel Wire Armoured Power Cable
Voltage designation
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of Uo/ U(Um)kV.
Where:
Uo-The rated power-frequency voltage between conductor and screen or metallic-sheath,for which the cable designed;
U-The rated power-frequency voltage between conductors, for which the cable designed:
Urn-The maximum value of the "hight system voltage " for which the equipment may he operated.
Rated voltaged of cable applied in three phrase system are given in table
U | Um | Uo |
First class | Second class |
1 | 1.2 | 0.6 | 0.6 |
3 | 3.6 | 1.8 | 3.6 |
6 | 7.2 | 3.6 | 6 |
10 | 12 | 6 | 8.7 |
15 | 17.5 | 8.7 | 12 |
20 | 24 | 12 | 18 |
35 | 42 | 21 | 26 |
Note:The first class cable suitable for one single-phrase earth-fault time does not exceed 1 min each time and Max. time not exceed 8 hours.and not exceed 125 hours in all in one year.
The second class cable suitable fir more earth-fault time and more better insulation performance.
Production Range of cable
Type | No. of cores | Nominal Cross sectional area m2 |
Copper conductor |
YJV33 | 2 | 10-400 |
3 | 10-630 |
4 | 10-500 |
3+1 | 10-630 |
5 | 10-500 |
4+1 | 10-500 |
3+2 | 10-500 |
*The armoured single-core cables are used for D.C system only. As for A.C system non-magnetic armoured material should be used. Or magnetic isolation measures should be applied. |
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
DIMENSIONS-YJV33 -Table 01
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | 0.6/1KV YJV33 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Sector |
2×10 | 0.7 | 20.0 | - | 912 |
2×16 | 0.7 | 22.0 | - | 920 |
2×25 | 0.9 | 25.6 | - | 1156 |
2×35 | 0.9 | 27.8 | - | 1328 |
2×50* | 1.0 | 30.0 | 26.4 | 1231 |
2×70* | 1.1 | 35.2 | 30.0 | 1733 |
2×95* | 1.1 | 39.0 | 34.0 | 2022 |
2×120* | 1.2 | 42.4 | 35.4 | 2328 |
2×150* | 1.4 | 47.2 | 40.6 | 3799 |
2×185* | 1.6 | 52.2 | 44.4 | 4305 |
2×240* | 1.7 | 57.8 | - | 5124 |
2×300* | 1.8 | 63.5 | - | 6408 |
* Compacted conductor
DIMENSIONS-YJV33 -Table 02
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | 0.6/1KV YJV33 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Sector |
3×10 | 0.7 | 20.8 | - | 1049 |
3×16 | 0.7 | 23.0 | - | 1323 |
3×25 | 0.9 | 26.9 | - | 1779 |
3×35 | 0.9 | 29.5 | - | 2174 |
3×50* | 1.0 | 31.8 | 28.6 | 2433 |
3×70* | 1.1 | 37.6 | 32.8 | 3429 |
3×95* | 1.1 | 41.8 | 37.0 | 4327 |
3×120* | 1.2 | 46.7 | 40.6 | 5567 |
3×150* | 1.4 | 51.4 | 45.1 | 7269 |
3×185* | 1.6 | 56.1 | 49.6 | 8466 |
3×240* | 1.7 | 62.1 | 54.2 | 10508 |
3×300* | 1.8 | 67.9 | 59.2 | 12831 |
3×400* | 2.0 | 76.5 | 66.0 | 17033 |
* Compacted conductor
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
DIMENSIONS-YJV33 -Table 03
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | 0.6/1KV YJV33 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Sector |
4×10 | 0.7 | 22.2 | - | 1217 |
4×16 | 0.7 | 24.6 | - | 1560 |
4×25 | 0.9 | 29.0 | - | 2132 |
4×35 | 0.9 | 31.9 | - | 2649 |
4×50* | 1.0 | 35.5 | 34.4 | 3218 |
4×70* | 1.1 | 40.9 | 38.8 | 4312 |
4×95* | 1.1 | 46.8 | 45.5 | 5468 |
4×120* | 1.2 | 57.5 | 48.6 | 7479 |
4×150* | 1.4 | 56.0 | 52.4 | 9090 |
4×185* | 1.6 | 61.9 | 59.6 | 10587 |
4×240* | 1.7 | 68.1 | 65.7 | 13238 |
4×300* | 1.8 | 75.9 | 72.1 | 16273 |
4×400* | 2.0 | 84.4 | 80.2 | 21519 |
*Compacted conductor
DIMENSIONS-YJV33 -Table 04
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | 0.6/1KV YJV33 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Tile Shape |
5×10 | 0.7 | 23.7 | - | 1391 |
5×16 | 0.7 | 26.4 | - | 1805 |
5×25 | 0.9 | 31.5 | - | 2510 |
5×35 | 0.9 | 35.4 | - | 3375 |
5×50* | 1.0 | 39.5 | - | 4093 |
5×70* | 1.1 | 45.1 | 42.6 | 5326 |
5×95* | 1.1 | 51.3 | 48.8 | 7432 |
5×120* | 1.2 | 56.0 | 52.4 | 8999 |
5×150* | 1.4 | 61.6 | 57.8 | 10936 |
5×185* | 1.6 | 67.7 | 63.0 | 12793 |
5×240* | 1.7 | 75.9 | 71.1 | 16041 |
5×300* | 1.8 | 83.6 | 77.9 | 20754 |
5×400* | 2.0 | 92.6 | - | 26123 |
*Compacted conductor
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
DIMENSIONS-YJV33 -Table 05
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | 0.6/1KV YJV33 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Sector |
3x10+1x6 | 3 | 0.7 | 21.5 | - | 1137 |
1 | 0.7 |
3x16+1x10 | 3 | 0.7 | 24.0 | - | 1471 |
1 | 0.7 |
3x25+1x16 | 3 | 0.9 | 27.9 | - | 1984 |
1 | 0.7 |
3x35+1x16 | 3 | 0.9 | 30.1 | - | 2372 |
1 | 0.7 |
3x50+1x25 | 3* | 1.0 | 34.0 | 35.2 | 2807 |
1 | 0.9 |
3x70+1x35 | 3* | 1.1 | 39.1 | 39.8 | 4012 |
1 | 0.9 |
3x95+1x50 | 3* | 1.1 | 43.4 | 45.3 | 5038 |
1 | 1.0 |
3x120+1x70 | 3* | 1.2 | 48.9 | 49.0 | 6809 |
1 | 1.1 |
3x150+1x70 | 3* | 1.4 | 52.8 | 53.2 | 7991 |
1 | 1.1 |
3x185+1x95 | 3* | 1.6 | 58.0 | 60.0 | 9444 |
1 | 1.1 |
3x240+1x120 | 3* | 1.7 | 64.1 | 66.5 | 11722 |
1 | 1.2 |
3x300+1x150 | 3* | 1.8 | 69.9 | 71.4 | 14392 |
1 | 1.4 |
3x400+1x185 | 3* | 2.0 | 79.3 | 81.0 | 18892 |
1 | 1.6 |
*Compacted conductor
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
DIMENSIONS-YJV33 -Table 06
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | 0.6/1KV YJV33 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Tile Shape |
4x10+1x6 | 4 | 0.7 | 23.1 | - | 1317 |
1 | 0.7 |
4x16+1x10 | 4 | 0.7 | 25.9 | - | 1722 |
1 | 0.7 |
4x25+1x16 | 4 | 0.9 | 30.5 | - | 2370 |
1 | 0.7 |
4x35+1x16 | 4 | 0.9 | 33.1 | - | 2858 |
1 | 0.7 |
4x50+1x25 | 4* | 1.0 | 38.3 | - | 3815 |
1 | 0.9 |
4x70+1x35 | 4* | 1.1 | 43.5 | 40.8 | 4920 |
1 | 0.9 |
4x95+1x50 | 4* | 1.1 | 48.9 | 46.8 | 6858 |
1 | 1.0 |
4x120+1x70 | 4* | 1.2 | 54.1 | 50.8 | 8318 |
1 | 1.1 |
4x150+1x70 | 4* | 1.4 | 58.2 | 55.0 | 9867 |
1 | 1.1 |
4x185+1x95 | 4* | 1.6 | 64.5 | 60.6 | 11681 |
1 | 1.1 |
4x240+1x120 | 4* | 1.7 | 71.0 | 66.6 | 14589 |
1 | 1.2 |
4x300+1x150 | 4* | 1.8 | 79.5 | 74.3 | 18951 |
1 | 1.4 |
4x400+1x185 | 4* | 2.0 | 87.9 | - | 23553 |
1 | 1.6 |
*Compacted conductor
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
DIMENSIONS-YJV33 -Table 07
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | 0.6/1KV YJV33 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
Circular | Tile Shape |
3x10+2x10 | 3 | 0.7 | 22.5 | - | 1244 |
2 | 0.7 |
3x16+2x10 | 3 | 0.7 | 25.3 | - | 1639 |
2 | 0.7 |
3x25+2x16 | 3 | 0.9 | 29.5 | - | 2217 |
2 | 0.7 |
3x35+2x16 | 3 | 0.9 | 31.3 | - | 2596 |
2 | 0.7 |
3x50+2x25 | 3* | 1.0 | 36.7 | - | 3494 |
2 | 0.9 |
3x70+2x35 | 3* | 1.1 | 41.7 | 40.6 | 4497 |
2 | 0.9 |
3x95+2x50 | 3* | 1.1 | 46.8 | 46.6 | 6265 |
2 | 1.0 |
3x120+2x70 | 3* | 1.2 | 52.3 | 50.8 | 7674 |
2 | 1.1 |
3x150+2x70 | 3* | 1.4 | 55.4 | 54.8 | 8866 |
2 | 1.1 |
3x185+2x95 | 3* | 1.6 | 61.4 | 60.4 | 10615 |
2 | 1.1 |
3x240+2x120 | 3* | 1.7 | 67.4 | 66.4 | 13161 |
2 | 1.2 |
3x300+2x150 | 3* | 1.8 | 75.1 | 73.7 | 16178 |
2 | 1.4 |
3x400+2x185 | 3* | 2.0 | 83.4 | - | 21091 |
2 | 1.6 |
*Compacted conductor
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
DIMENSIONS-YJV33 -Table 08
Product Data Of Cable
Nominal cross-sectional area of conductor(mm²) | Max.D.C resistance of conductor at 20ºC(Ω/km) |
Copper |
1 | 18.1 |
1.5 | 12.1 |
2.5 | 7.41 |
4 | 4.61 |
6 | 3.08 |
10 | 1.83 |
16 | 1.15 |
25 | 0.727 |
35 | 0.524 |
50 | 0.387 |
70 | 0.268 |
95 | 0.193 |
120 | 0.153 |
150 | 0.124 |
185 | 0.0991 |
240 | 0.0754 |
300 | 0.0601 |
400 | 0.0470 |
500 | 0.0366 |
630 | 0.0283 |
800 | 0.0021 |
Power frequency A.C. Voltage test | Test voltage 3.5kV/5 min |
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
Current carrying capacity of cable
l In the air
Conductor | Nominal Cross sectional area of conductor mm2 | Armoured cable |
Single Core | Two Core | Three cores & Five cores |
| |
Copper Conductor | 1.5 | 21 | 24 | - | - |
2.5 | 31 | 41 | - | - |
4 | 41 | 54 | - | - |
6 | 52 | 68 | - | - |
10 | 71 | 93 | 75 | 64 |
16 | 92 | 120 | 97 | 83 |
25 | 120 | 155 | 125 | 110 |
35 | 150 | 195 | 155 | 135 |
50 | 180 | 235 | 190 | 165 |
70 | 230 | 295 | 245 | 210 |
95 | 285 | 370 | 300 | 260 |
120 | 335 | 430 | 355 | 305 |
150 | 385 | 495 | 400 | 345 |
185 | 450 | 570 | 460 | 395 |
240 | 535 | 680 | - | 465 |
300 | 620 | 790 | - | 535 |
400 | 720 | 920 | - | 620 |
500 | 835 | 1080 | - | - |
630 | 960 | 1260 | - | - |
800 | 1110 | 1470 | - | - |
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
Current carrying capacity of cable
l In the ground
Conductor | Nominal Cross sectional area of conductor mm2 | Armoured cable |
Single Core | Two Core | Three cores & Five cores |
| |
Copper Conductor | 1.5 | 25 | 28 | - | - |
2.5 | 42 | 46 | 45 | 35 |
4 | 55 | 59 | 59 | 50 |
6 | 69 | 74 | 74 | 60 |
10 | 92 | 98 | 100 | 85 |
16 | 115 | 125 | 135 | 110 |
25 | 150 | 160 | 165 | 140 |
35 | 180 | 190 | 200 | 170 |
50 | 215 | 230 | 240 | 200 |
70 | 265 | 280 | 295 | 245 |
95 | 320 | 335 | 355 | 300 |
120 | 360 | 385 | 405 | 335 |
150 | 410 | 430 | 455 | 380 |
185 | 460 | 490 | 515 | 430 |
240 | 535 | 570 | - | 500 |
300 | 605 | 645 | - | 565 |
400 | 685 | 735 | - | 650 |
500 | 775 | 840 | - | - |
630 | 865 | 950 | - | - |
800 | 960 | 1080 | - | - |
Find this product online: wxjncable.com | Cables & Accessories
Power Cable | 0.6/1KV Copper Conductor XLPE Insulated Steel Wire Armoured PE Sheathed Power Cable
Installation and Operation Condition of Cable
l In the air
1.The distance between two adjacent cable' axle centers of single-core cables laid in parallel cross-section area of conductor≤185mm²;2 times of the cable diameter cross-sectional area of conductor≥240mm²;90mm
2.Ambient air temperature:30ºC.
3.Max.continous operating temperature of conductor: 90ºC.
l Current carrying rating factors for different ambient air temperature
Ambient air temperature | 20ºC | 25ºC | 30ºC | 35ºC | 40ºC | 45ºC |
Correction factor | 1.09 | 1.04 | 1.00 | 0.95 | 0.90 | 0.84 |
l Directly in the ground
1.The single-core cables are installed separately.The distance between the cable
center is 2 times of the cable Diameter.
2.Soil temperature: 25ºC.
3.Max.continous operating temperature of
conductor: 90ºC.
4.Thermal resistivity of soil : 1.0 ºC. m/W
5.Depth of Direct-Buried:0.7m.
l Current carrying rating factors for different soil temperature
Soil temperature | 20ºC | 25ºC | 30ºC | 35ºC | 40ºC |
Correction factor | 1.04 | 1.0 | 0.96 | 0.92 | 0.87 |