0, 46019
Business Type:
Trading Company
Business Range:
Conductor (AAC/ACSR/AAAC/ACSR-AW),1kV PVC Insulate,
Management System Certification:
Terms of Payment:
LC, T/T, D/P
OEM/ODM Availability:
No
OEM/ODM Service
Sample Available
MEI Awards
Trial Member 5 years
Audited Supplier
Supplier Homepage Electronic Electronic circuit cooling components heat sink Overhead Transmission Aluminium Cable Duplex Service Drop ABC Cable

Overhead Transmission Aluminium Cable Duplex Service Drop ABC Cable

Purchase Qty. / Reference FOB Price
Production Capacity:
Payment Terms: LC, T/T, D/P

Basic Info

Model NO.
duplex CABLE
Material Shape
Round Wire
Range of Application
Primarily Overhead Secondary Distribution
Certification
ISO9001, CCC
Brand
Jytop
Standard
Asrm B-230 / Asrm B-231/ Asrm B-232/Asrm B-399
Ambient Temperature
25 ºC
Ampacity Rating
75ºC
Emissivity
0.91
Coefficient of Absorbtion
0.95
Trademark
JYTOP
Transport Package
500m / Rolls
Specification
ASTM standards
Origin
Zhengzhou, China
HS Code
8544492100
Overhead Transmission aluminium cable Duplex Service Drop abc Cable 

Construction:

Conductors are concentric stranded or compressed conductors of aluminum 1350-H19 covered for weather proofing with polyethylene, High Density polyethylene (HDPE) or Cross-linked polyethylene (XLPE) insulation, concentric stranded AAC,ACSR or 6210 AAAC alloy neutral messenger.
 


 
Applications:
Duplex Service Drop is to supply 120V or 240V and below aerial service for temporary service at construction sites, outdoor or street lighting, for service at 600V or below at a conductor temperature of 70ºC maximum for polyethylene insulation , or 90ºC maximum for cross-linked polyethylene insulation.
 
Standards:
Duplex service drop cable  meets or exceeds the following ASTM specifications:
ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-399 Concentric-Lay-Stranded Aluminum Alloy Conductors 6201-T81.
Service drop conductor meets or exceeds all applicable requirement of ANSI/ ICEA-S-76-474:
Ampacity rating base on 75ºC conductor temperature; 25ºC ambient temperature. Emissivity 0.91 and coefficient of absorbtion of 0.95.

  
Code WordPhase ConductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG or kcmil)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingInsul. Thick. (mils)Rated Strength (lbs.)XLPPOLYXLPPOLY
6201 ALLOY NEUTRAL-MESSENGER
Chihuahua6145630.587111065658570
Vizsla6745630.587111068688570
Harrier4145448.6971760999911590
Whippet4745448.697176010310311590
Schnauzer2745277.4772800157157150120
Heeler1/09601/0123.374460250250205160
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++ Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 

Code WordPhase ConductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG or kcmil)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
AAC NEURAL-MESSENGER
Pekingese61456756361618570
Collie67456756364648570
DachShund414547881929211590
Spaniel474547881969611590
Doberman2745271350147147150120
Bull1/09601/071990234234205160
* Code Words For XLP Insulated Products Are Formed By Adding "/XLP" to the Conventional Code Words Above (e.g.-Chihuahua/XLP).+ Conductor Temperature of 90°C For XLP, 75°C For Poly; Ambient Temperature of 40°C; Emissivity 0.9; 2 ft./sec. Wind In Sun.

 

Code WordPhase ConductorBare Neutral MessengerWeight Per 1000 ft. (lbs.)Allowable Ampacity+
Size (AWG or kcmil)StrandingInsul. Thick. (mils)Size (AWG)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
ACSR NEUTRAL-MESSENGER
Setter614566/1119072728570
Shepherd674566/1119075758570
Eskimo414546/1186011011011590
Terrier474546/11860115115150120
Chow274526/12850176176150120
Bull1/09601/06/14380280280205160
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

 

 

 

Send Inquiry to this supplier

People who viewed this also viewed

FOB Price: US $1 / Meter
Min. Order: 5000 Meters
FOB Price: US $1 / Meter
Min. Order: 5000 Meters
FOB Price: US $1 / Meter
Min. Order: 5000 Meters
FOB Price: US $0.5 / Meter
Min. Order: 5000 Meters

You Might Also Like

FOB Price: US $4569/piece
FOB Price: US $4568/piece
FOB Price: US $0.6 / Piece
Min. Order: 100 Pieces
FOB Price: US $2.68 / Meter
Min. Order: 500 Meters
FOB Price: $20 - $60 / Box
Min. Order: 100 Boxes
FOB Price: $20 - $60 / Box
Min. Order: 100 Boxes
FOB Price: $0.5 - $0.8 / Piece
Min. Order: 10 Pieces

Send Inquiry to this supplier

Contact Us | User Agreement | Privacy Policy | 加入会员

Service Tel: (+86)0571-87774297