Application
System Connection Wire
Conductor Material
Copper
Range of Application
System Connection Wire
Certification
ISO9001, CE, CCC, RoHS
Name
PVC Insulation PVC Sheath Control Wire (Kvv)
Specification
BSI, CE, ROHS
APPLICATION
Copper Conductor PVC Insulated PVC Sheathed Rigid Control Cable(KVV) is mainly used for system connection wire of control,signal,protection or measuring for rated voltage up to and including 450/750V.
BASIC INFORMATION
Code Name
KVV
Rated Voltage (Uo/U)
450/750V
Cable Structure
CU/PVC Insulation/PVC Sheathed
CONSTRUCTION
Conductor
Preferred Number of cores:
2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52,61
The conductors shall comply with the requirement given in IEC 60228 for class 1 or 2.
- class 1 for solid conductors;
- class 2 for stranded conductors.
Insulation
PVC(Polyvinyl Chloride) Type PVC/A according to IEC
Sheathed
PVC(Polyvinyl Chloride) Type PVC/ST1 according to IEC
Other special application cable can be provided upon requests:
Fire-resistant,Flame-retardant,Low-halogen,Non-halogen,Low-fume,Low-smoke,as well as acid-alkali-proof,High temperature resistant,Termite and Rodent resistant,Water proof series and so on.
CABLE STANDARDS
GB/T,JB/T,IEC,BS,VDE up on request.
The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the JiangNan Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed.
CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 70ºC
Installation temperature
Ambient temperature under installation shall not be below 0ºC
Max.temperature of conductor under short circuit
-(Max.Duration 5 sec.)
PVC Insulated:160ºC
Preferred Permissible bending radius
For non-armoured PVC insulated cable not less than: 6 times of cable diameter
Production Scope Of Control Cable(KVV)
Type | Nominal Cross Sectional Area of Conductor(mm2) |
KVV | 0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 |
No. of Cores |
/ | 2~61 | 2~14 | 2~10 |
Dimensions And D.C Resistance-PVC Sheathed Control Cable(KVV)
Nominal Cross Sectional Area of Conductor(mm2) | Class of conductor | Max.D.C.Resistance at 20ºC(Ω/km) |
Plain | Metal-coated |
0.75 | 1 | 24.5 | 24.8 |
0.75 | 2 | 24.5 | 24.8 |
1.0 | 1 | 18.1 | 18.2 |
1.0 | 2 | 18.1 | 18.2 |
1.5 | 1 | 12.1 | 12.2 |
1.5 | 2 | 12.1 | 12.2 |
2.5 | 1 | 7.41 | 7.56 |
2.5 | 2 | 7.41 | 7.56 |
4 | 1 | 4.61 | 4.70 |
4 | 2 | 4.61 | 4.70 |
6 | 1 | 3.08 | 3.11 |
6 | 2 | 3.08 | 3.11 |
10 | 2 | 1.83 | 1.84 |