Application
Underground, Control Cable
Conductor Material
Copper
Material Shape
Round Wire
Range of Application
Electric Equipemt Connections
Certification
ISO9001, CE, UL, CCC
VDE standrad YY PVC insulated shield control cable
Application:Designed to offer a flexible solution for signalling, measuring and control applications.This range of cables are not only flexible but offer heat and oil protection.
Standards: Generally to BS6500 and VDE0250
Conductor: Flexible class 5 copper conductors to BS6360 / VDE0295
Insulation: PVC
Sheath: PVC
Voltage Rating: 300/500V
Temperature rating: Flexing -15 to +70°C
Static -35 to +70°C
Minimum bending radius: 6 x overall diameter
Core identification: Black with White numbers. (3 core and above to include Green/Yellow) Coloured cores available on request .
Current Carrying Capacity (amperes)
Nominal Cross Sectional Area
Single Phase AC or DC
Three Phase AC
mm2
Amps
Amps
0.75
6
6
1.0
10
10
1.5
16
16
2.5
25
20
4.0
32
25
6.0
51
43
10.0
70
60
16.0
94
80
For ambient air temperatures other than 30°C the following rating factors should be applied:
Ratings for cables up to and including 4mm2 are based on 60°C conductor operating temperature with 6mm2 and above based on 70°C operating temperature
Correction Factors
Cables Up To and Including 4mm2 , Assuming 60°C Conductor Temperature
Ambient Temperature
35°C
40°C
45°C
50°C
55°C
Correction Factor
0.91
0.82
0.71
0.58
0.41
Cables 6mm2 and above, Assuming 70°C Conductor Temperature
Ambient Temperature
35°C
40°C
45°C
50°C
55°C
60°C
Correction Factor
0.91
0.82
0.71
0.58
0.41
0.50
3 core YY control cable specification
specification
Number of Cores
Nominal Cross Sectional Area
mm2
No. and Nominal Diameter of Strands
#/mm
Nominal Overall Diameter
mm
Nominal Weight
kg/ km
3C0.75SQ
3
0.75
24/0.20
5.9
55
3C1.00SQ
3
1.0
32/0.20
6.4
67
3C1.50SQ
3
1.5
30/0.25
7.4
92
3C2.50SQ
3
2.5
50/0.25
9.5
153
3C4.00SQ
3
4.0
56/0.30
12.0
235
3C6.00SQ
3
6.0
84/0.30
12.8
305
3C10.0SQ
3
10.0
80/0.40
15.8
590
3C16.0SQ
3
16.0
126/0.40
18.4
800
4 core YY control cable
Item.
Number of Cores
Nominal Cross Sectional Area
mm2
No. and Nominal Diameter of Strands
#/mm
Nominal Overall Diameter
mm
Nominal Weight
kg/ km
4C0.75SQ
4
0.75
24/0.20
6.8
76
4C1.00SQ
4
1.0
32/0.20
7.4
89
-4C1.50SQ
4
1.5
30/0.25
8.5
122
4C2.50SQ
4
2.5
50/0.25
10.4
191
4C4.00SQ
4
4.0
56/0.30
13.5
330
4C6.00SQ
4
6.0
84/0.30
16.0
480
4C10.0SQ
4
10.0
80/0.40
20.8
743
4C16.0SQ
4
16.0
126/0.40
24.1
1104
5 core YY control cable
item
Number of Cores
Nominal Cross Sectional Area
mm2
No. and Nominal Diameter of Strands
#/mm
Nominal Overall Diameter
mm
Nominal Weight
kg/ km
5C0.75SQ
5
0.75
24/0.20
7.4
88
5C1.00SQ
5
1.0
32/0.20
8.1
108
5C1.50SQ
5
1.5
30/0.25
9.3
148
5C2.50SQ
5
2.5
50/0.25
11.7
241
5C4.00SQ
5
4.0
56/0.30
14.7
404
5C6.00SQ
5
6.0
84/0.30
17.2
592
5C10.0SQ
5
10.0
80/0.40
22.9
920
5C16.0SQ
5
16.0
126/0.40
28.4
1370
7 core YY control cable
item
Number of Cores
Nominal Cross Sectional Area
mm2
No. and Nominal Diameter of Strands
#/mm
Nominal Overall Diameter
mm
Nominal Weight
kg/ km
7C0.75SQ
7
0.75
24/0.20
8.0
113
7C1.00SQ
7
1.0
32/0.20
8.8
140
7C1.50SQ
7
1.5
30/0.25
10.1
193
7C2.50SQ
7
2.5
50/0.25
12.9
311
for more information,welcome to contact us directly