Standards and Scope of Application The products are used for aerial electric power transmission according to the standard ASTM , IEC , BS , CSA , NFC , and so on
Specific property for using 1.The permissible long-time operating temperature for aerial conductor is 70 C 2.For long-span application in harsh environment such as heavy icing , the biggest stress of the cable at the lowest point on the span curve shall not exceed 60% of its breaking load. 3.When connecting conductors , the conductor near the connecting tube can"t be prominent. Otherwise , the force on the operating conductors will be unbalanced after connectors are pressed . The connecting tube should be plated by moistureproof paint in order to avoid corrosion. 4.In order to meet conductor-to-earth or conductor-to-building distance requirement during installation , the conductor stress can be 10%~15% higher than its permissible normal tension .
DESCRIPTION 1.Good conductiveity:The conductivity is the same as pure copper wire when the frequency is higher than 5MHZ. 2.Save copper resource , reduce the produce cost : The CCA"s density is 37~40 percent of the purecopper wire , and the length is 2.5 times of pure copper wire with the same weight .
STANDARDS Construction as per ASTM , IEC , BS , DIN , CSA , NFC ,and so on.
APPLICATION
It can be widely used in CATV Coaxial cable , RF cable , LAN cable , Computer cable and Power cable , Magnet wire , and power transmition etc . The CCA we can produce is 0.04~5.15mm , and we also can produce as customer"s requirements .