Purchase Qty. / Reference FOB Price | |
---|---|
1 piece | US $ |
Production Capacity: | 1147 |
---|---|
Payment Terms: |
Series:Power Grid Automation and Communication Products
Product Description
RET650 provides the best'off the shelf'solution for protecting two winding and three winding transformers.The RET650 IED(Intelligent Electronic Device)variant,which has undergone type testing,is delivered with complete functionality and default parameters configured for easy product handling-from ordering,engineering,and debugging to reliable operation.
The 650 series IEDs(Intelligent Electronic Devices)have many useful features,such as significantly reduced number of parameter settings and expanded IED HMI functionality,including 15 dynamic three color indicator LEDs per page(up to three pages)and configurable button shortcuts for different operations.
In the 650 series IEDs,the most basic parameters are set before leaving the factory.You only need to set parameters specific to your application.This allows you to quickly put IEDs into operation.The application manual includes examples of settings that provide support for your protection engineer.
Relion-Complete Confidence
Transformer protection RET650 IED belongs to the Relion protection and control product series.The Relion product series offers a variety of products for power system protection,control,measurement,and monitoring.To ensure that the solution is interoperable and future-oriented,the design of Relion products aims to achieve the core values of the IEC 61850 standard.With Hitachi Energy's leading technology,global application knowledge,and experienced support network,you can fully trust that your system can operate reliably in any situation.
Unmatched sensitivity and speed
RET650 provides the best coverage range for inter turn faults in power transformer windings,and its unique negative sequence internal/external fault discriminator is faster than traditional stable transformer differential protection functions.It can also achieve extremely sensitive protection to detect constantly changing internal faults,so that the system can trip before a more severe fault with severe damage occurs.RET650 has low requirements for the main CT and does not require an intermediate CT.
The low impedance limited grounding fault function of all direct or low impedance grounded windings provides excellent stability for external faults.Each winding is individually protected without the need for harmonic stability,ensuring high sensitivity and fast tripping.The directional zero sequence current standard added to this function improves safety.
The overcurrent function provides necessary backup protection.The thermal overload function can prevent the transformer from being damaged due to overload.Circuit breaker fault protection allows for high-speed backup tripping of surrounding circuit breakers and re tripping of its own circuit breaker.
RET650 provides you with futuristic concepts based on application flexibility,making it an excellent choice for new and retrofitted installations.The integration of main protection and a series of backup protection functions within IED can improve the performance of your power system.It also reduces hardware engineering and installation time,as well as space and spare parts requirements.
application area
power plant
transformer substation
Industrial electricity
Contact Us | User Agreement | Privacy Policy | 加入会员