Model NO.
ABC Electric Cable
Material Shape
Round Wire
Range of Application
Oveahead
Certification
ISO9001, CE, CCC, RoHS
Color
as Per Your Customers ′ Request
Insulated Materials
PVC/PE/XLPE
Transport Package
All Wooden, Steel Wooden or Steel Package
Aluminum Conductor XLPE Insulated ABC Electric Cable
1.Properties
ABC cable is primarily used on lighting, outdoor lighting, and temporary service for construction.
To be used at voltages of 600V phase-to-phase or less,
and the conductor temperatures no exceeds 75 degrees for polyethylene(PE) insulated conductors or 90 degrees for corsslinked polyethylene(XLPE) insulated conductors.
2. Application of Service Drop Cables
2.1 DuplexService Drop
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower ATA conductor temperature of 750C maximum.
2.2 Triplex Service Drop
To supply power from the utility`s lines to the consumer`s weather head. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
2.3 Quadruplex Service Drop
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
3. Construction
Concentric stranded or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
4.ABC cable meets of exceeds the following specifications
Aluminum cable,1350-H19 for electrical purposes.
Aluminum conductors,concentric lay stranded.
Aluminum conductor,concentric lay stranded,coated steel reinforced(ACSR).
Concentric lay stranded,6201-T81 conductors.
Compressed round stranded aluminum conductors using single input conductor.
Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.
Aerial Bundled Cable, ABC Cable, Overhead cable,ASTM, BS, NFC, IEC, DIN Standard
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM, BS, NF C 33-209 standard.
LV ABC cable(Aerial Bundle cable) with AAAC conductor
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, Duplex, Triplex, Quadruplex.
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Code word | AWG or kcmil | Bare neutral messenger | Phase conductor | Weight kg/km |
ACSR stranding and wires dia. (mm) | Rated strength (lbs) | AAC | Insulation thickness (mm) |
Stranding and wires dia. (mm) |
Setter | 1*6AWG+1*6AWG | 1/1.68+6/1.68 | 1190 | 1/4.11 | 1.14 | 111 |
Shepherd | 1*6AWG+1*6AWG | 1/1.68+6/1.68 | 1190 | 7/1.56 | 1.14 | 113 |
Eskimo | 1*4AWG+1*4AWG | 1/2.12+6/2.12 | 1860 | 1/5.19 | 1.14 | 171 |
Terrier | 1*4AWG+1*4AWG | 1/2.12+6/2.12 | 1860 | 7/1.96 | 1.14 | 173 |
Chow | 1*2AWG+1*2AWG | 1/2.67+6/2.67 | 2850 | 7/2.47 | 1.14 | 266 |
Bull | 1*1/0AWG+1*1/0AWG | 1/3.37+6/3.37 | 4380 | 19/1.89 | 1.52 | 427 |