Purchase Qty. / Reference FOB Price |
---|
Production Capacity: | |
---|---|
Payment Terms: | LC, T/T, D/P, PayPal, Western Union, Small-amount |
China supplier AAC aluminum wire all aluminium conductor for hot sale
Huatong Cable Inc--Professional Cable and Conductor Manufacturer
Company profile :Huatong Cable Inc.China supplier AAC aluminum wire all aluminium conductor for hot sale
APPLICATIONS
Classes 1 AA and A are used primarily for overhead transmission and primary and secondary distribution, where ampacity must be maintained and a lighter conductor (compared to ACSR) is desired, and when conductor strength is not a critical factor. Classes B and C are used primarily as bus, apparatus connectors and jumpers, where additional flexibility is required.
SPECIFICATIONS
Huatong"s AAC bare conductor meets or exceeds the following ASTM specifications:
• B230 Aluminum 1350-H19 Wire for Electrical Purposes.
• B231 Concentric-Lay-Stranded Aluminum 1350 Conductors.
CONSTRUCTION
Aluminum 1350-H19 wires, concentrically stranded.
IEC 61089
Code Number | Area | Number of Wires | Diameter | Linear Mass | Rated Strength | Max.D.C.Resistence at 20ºC | |
mm2 | Wire | Cond. | kg/km | kN | Ω/km | ||
10 | 10 | 7 | 1.35 | 4.05 | 27.4 | 1.95 | 2.8633 |
16 | 16 | 7 | 1.71 | 5.12 | 43.8 | 3.04 | 1.7896 |
25 | 25 | 7 | 2.13 | 6.4 | 68.4 | 4.5 | 1.1453 |
40 | 40 | 7 | 2.7 | 8.09 | 109.4 | 6.8 | 0.7158 |
63 | 63 | 7 | 3.39 | 10.2 | 172.3 | 10.39 | 0.4545 |
100 | 100 | 19 | 2.59 | 12.9 | 274.8 | 17 | 0.2877 |
125 | 125 | 19 | 2.89 | 14.5 | 343.6 | 21.25 | 0.2302 |
160 | 160 | 19 | 3.27 | 16.4 | 439.8 | 26.4 | 0.1798 |
200 | 200 | 19 | 3.66 | 18.3 | 549.7 | 32 | 0.1439 |
250 | 250 | 19 | 4.09 | 20.5 | 687.1 | 40 | 0.1151 |
315 | 315 | 37 | 3.29 | 23 | 867.9 | 51.97 | 0.0916 |
400 | 400 | 37 | 3.71 | 26 | 1102 | 64 | 0.0721 |
450 | 450 | 37 | 3.94 | 27.5 | 1239.8 | 72 | 0.0641 |
500 | 500 | 37 | 4.15 | 29 | 1377.6 | 80 | 0.0577 |
560 | 560 | 37 | 4.39 | 30.7 | 1542.9 | 89.6 | 0.0515 |
630 | 630 | 61 | 3.63 | 32.6 | 1738.3 | 100.8 | 0.0458 |
710 | 710 | 61 | 3.85 | 34.6 | 1959.1 | 113.6 | 0.0407 |
800 | 800 | 61 | 4.09 | 36.8 | 2207.4 | 128 | 0.0361 |
900 | 900 | 61 | 4.33 | 39 | 2483.3 | 144 | 0.0321 |
1000 | 1000 | 61 | 4.57 | 41.1 | 2759.2 | 160 | 0.0289 |
1120 | 1120 | 91 | 3.96 | 43.5 | 3093.5 | 179.2 | 0.0258 |
1250 | 1250 | 91 | 4.18 | 46 | 3452.6 | 200 | 0.0231 |
1400 | 1400 | 91 | 4.43 | 48.7 | 3866.9 | 224 | 0.0207 |
1500 | 1500 | 91 | 4.58 | 50.4 | 4143.1 | 240 | 0.0193 |
ASTM B 231
Code Name | Total Area | Stranding and Wire Diameter | Overall Diameter | Liner Mass | Nominal Breaking Load | Max. D.C. Resistance at 20ºC | |
AWG or MCM | mm² | mm | mm | kg/km | daN | Ω/km | |
Peachbell | 6 | 13.29 | 7/1.554 | 4.67 | 37 | 249 | 2.1692 |
Rose | 4 | 21.16 | 7/1.961 | 5.89 | 58 | 396 | 1.3624 |
Iris | 2 | 33.61 | 7/2.474 | 7.42 | 93 | 597 | 0.8577 |
Pansy | 1 | 42.39 | 7/2.776 | 8.33 | 117 | 732 | 0.6801 |
Pappy | 1/0 | 53.48 | 7/3.119 | 9.36 | 147 | 873 | 0.539 |
Aster | 2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 1100 | 0.4276 |
Phlox | 3/0 | 85.03 | 7/3.932 | 11.8 | 234 | 1347 | 0.339 |
Oxlip | 4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 1698 | 0.2688 |
Valerian | 250 | 126.71 | 19/2.913 | 14.57 | 349 | 2062 | 0.2275 |
Sneezewort | 250 | 126.71 | 7/4.80 | 14.4 | 349 | 2007 | 0.2275 |
Laurei | 266.8 | 135.16 | 19/3.01 | 15.05 | 373 | 2200 | 0.2133 |
Dalsy | 266.8 | 135.16 | 7/4.96 | 14.9 | 373 | 2141 | 0.2133 |
Peany | 300 | 152 | 19/3.193 | 15.97 | 419 | 2403 | 0.1896 |
Tulip | 336.4 | 170.45 | 19/3.381 | 16.01 | 470 | 2695 | 0.1691 |
Daftodil | 350 | 177.35 | 19/3.447 | 17.24 | 489 | 2804 | 0.1625 |
Canna | 397.5 | 201.42 | 19/3.673 | 18.36 | 555 | 3184 | 0.1431 |
Goldentufl | 450 | 228 | 19/3.909 | 19.55 | 629 | 3499 | 0.1264 |
Syringa | 477 | 241.68 | 37/2.882 | 20.19 | 666 | 3849 | 0.1193 |
Cosmos | 477 | 241.68 | 19/4.023 | 20.12 | 666 | 3708 | 0.1193 |
Hyacinth | 500 | 253.35 | 37/2.951 | 20.65 | 698 | 4035 | 0.1138 |
Zinnia | 500 | 253.35 | 19/4.12 | 20.6 | 698 | 3888 | 0.1138 |
Dahlia | 556.5 | 282 | 19/4.346 | 21.73 | 777 | 4327 | 0.1022 |
Mistletoe | 556.5 | 282 | 37/3.114 | 21.79 | 777 | 4362 | 0.1022 |
Meadowsweet | 600 | 304 | 37/3.233 | 22.63 | 838 | 4703 | 0.0948 |
Orchid | 636 | 322.25 | 37/3.33 | 23.31 | 888 | 4985 | 0.0894 |
Heuchera | 650 | 329.35 | 37/3.366 | 23.56 | 908 | 5095 | 0.0875 |
Flag | 700 | 354.71 | 61/2.72 | 24.48 | 978 | 5146 | 0.0813 |
Code name | Nominal | Number | Cross- | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC |
( mm² ) | ( mm ) | ( mm² ) | ( mm ) | ( kg/km ) | daN | Ω/km | |
Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
Code Number | Caculated Area | Stranding and wire Diameter | Overall Diameter | Linear Mass | Calculated Breaking Load | Max D.C.Resistance at 20ºC |
mm2 | mm2 | mm | mm | kg/km | daN | Ω,km |
16 | 15.89 | 7/1.70 | 5.1 | 44 | 290 | 1.8018 |
25 | 24.25 | 7/2.10 | 6.3 | 67 | 425 | 1.1808 |
35 | 34.36 | 7/2 50 | 7.5 | 94 | 585 | 0.8332 |
50 | 49.48 | 7/3.00 | 9 | 135 | 810 | 0.5786 |
50 | 48.36 | 19/1.80 | 9 | 133 | 860 | 0.595 |
70 | 65.82 | 19/2.10 | 10.5 | 181 | 1150 | 0.4371 |
95 | 93.27 | 19/2.50 | 12.5 | 256 | 1595 | 0.3084 |
120 | 117 | 19/2.50 | 14 | 322 | 1910 | 0.2459 |
150 | 147.1 | 37/2.25 | 15.2 | 406 | 2570 | 0.196 |
185 | 181.6 | 37/2.50 | 17.5 | 501 | 3105 | 0.1587 |
240 | 242.54 | 61/2.25 | 20.2 | 670 | 4015 | 0.1191 |
300 | 299.43 | 61/2.50 | 22.5 | 827 | 4850 | 0.0965 |
400 | 400.14 | 61/2.89 | 26 | 1105 | 6190 | 0.07221 |
500 | 499.83 | 61/3.23 | 29.1 | 1381 | 7600 | 0.05781 |
625 | 626.2 | 91/2.96 | 32.6 | 1733 | 9690 | 0.04625 |
500 | 802.1 | 91/3.35 | 36.8 | 2219 | 12055 | 0.03611 |
1000 | 999.71 | 91/3.74 | 41.1 | 2766 | 14845 | 0.02897 |
ACSRAPPLICATIONS Classes 1 AA and A are used primarily for overhead transmission and primary and secondary distribution, where ampacity must be maintained and a lighter conductor (compared to ACSR) is desired, and when conductor strength is not a critical factor. Classes B and C are used primarily as bus, apparatus connectors and jumpers, where additional flexibility is required. | |
ABC cableAPPLICATIONS Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors. | |
Power cableApplication Properties Rated voltage U0/U:0.6/1KV,1.8/3KV The permitted temperature for long-time operation:90ºC Cable temperature shouldn"t exceed 250ºC at a short circuit with a lasting time shorter than 5s. The bend radius for laying: Single core cable>20 times of outer diameter of cable Multi-core >15 times of outer diameter of cable. |
Company | Huatong Cable Inc. |
Company website | www.htcable.cn |
Name | Daisy |
Mob | 00 86 13140169190 |
daisyyang1130 |
FAQ
1.How many years has Huatong Cable Inc. been in production?
Founded in 1993 , has made outstanding contribution to STATE GRID, CHINA SOUTH POWER GRID and the construction of domestic and foreign power market.
2. What kinds of products does Huatong Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4)PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
CCC, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 5000 tons within one month. For power cables, that depends on the type and size.
8. Do you supply the customers with installation service in foreign country ?
We don"t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
Contact Us | User Agreement | Privacy Policy | 加入会员
Service Tel: (+86)0571-87774297