Material Shape
Round Wire
Range of Application
Overhead Line
Certification
ISO9001, CE, CCC
Standards
ANSI/Icea S-76-474
Use
Overhead or Underground
Other Name
Messenger Wire
HS Code
8544492100, 8544492100
Transport Package
Wood Drum or Steel- Wood Drum
Specification
Aluminium 1350 with XLPE insulation
AAC/AAAC Conductor PVC/XLPE Insulated ABC Cable
The basic construction is as follows:
3 power cores consisting of standard aluminium conductors, insulated withXLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.
IF YOUR HAVE ANY INTERESTED PRODUCTS, PLS FEEL FREE TO CONTACT OUR SALES TEAM.
Single core
Code Word | Size (AWG or kcmil) | Stranding | Insul.Thick.(mils) | Diameter(mils) | Weight Per 1000 feet(Ibs.) | Allowable Ampacities+ |
Bare | Complete Cable |
Direct Burial | In Ducts |
Princeton | 6 | 7 | 60 | 178 | 298 | 44 | 90 | 65 |
Mercer | 4 | 7 | 60 | 225 | 345 | 63 | 120 | 85 |
Clemson | 2 | 7 | 60 | 283 | 403 | 92 | 155 | 115 |
Kenyon | 1 | 9 | 80 | 313 | 473 | 121 | 175 | 130 |
Harvard | 1/0 | 9 | 80 | 352 | 512 | 146 | 200 | 150 |
Yale | 2/0 | 11 | 80 | 395 | 555 | 177 | 225 | 170 |
Tufts | 3/0 | 17 | 80 | 443 | 603 | 215 | 250 | 195 |
Beloit | 4/0 | 18 | 80 | 498 | 658 | 263 | 290 | 225 |
Hofstra | 250 | 26 | 95 | 542 | 732 | 315 | 320 | 250 |
Gonzaga | 300 | 37 | 95 | 594 | 784 | 369 | 355 | 280 |
Rutgers | 350 | 37 | 95 | 641 | 831 | 422 | 385 | 305 |
Emory | 500 | 37 | 95 | 790 | 980 | 580 | 465 | 370 |
Duke | 600 | 61 | 110 | 866 | 1086 | 699 | 510 | 410 |
Furman | 700 | 61 | 110 | 935 | 1155 | 803 | 550 | 440 |
Sewanee | 750 | 61 | 110 | 968 | 1188 | 854 | 580 | 470 |
Fordham | 1000 | 61 | 110 | 1117 | 1337 | 1109 | 670 | 545 |
Code Word | Phase Conductor | Neutral | Diameter (mils) | Weight Per 1000ft (Ibs.) | Allowable Ampacities+ |
Size (AWG) | Stranding | Insul. Thick. (mils) | Size (AWG) | Stranding | Insul. Thick. (mils). | Single phase cond. | Conductor Cable |
Direct Burial | In Ducts |
DUPLEX WITH YELLOW EXTRUDED STRIPE NEUTRAL |
Bard | 8 | 7 | 60 | 8 | 7 | 60 | 262 | 524 | 64 | 70 | 55 |
Claflin | 6 | 7 | 60 | 6 | 7 | 60 | 298 | 596 | 89 | 95 | 70 |
Delgado | 4 | 7 | 60 | 4 | 7 | 60 | 345 | 690 | 127 | 125 | 90 |
+Ampacity:90ºC conductor temperature,20ºC ambient,RHO 90,100% load factor,For NEC Applications,use NEC Table310.16 Ampacities. |
|
Code Word | Phase Conductor | Neutral | Diameter (mils) | Weight Per 1000ft (Ibs.) | Allowable Ampacities+ |
Size (AWG) | Stranding | Insul. Thick. (mils) | Size (AWG) | Stranding | Insul. Thick. (mils). | Single phase cond. | Conductor Cable |
Direct Burial | In Ducts |
TRIPLEXED WITH YELLOW EXTRUDED STRIPE NEUTRAL |
Erskine | 6 | 7 | 60 | 6 | 7 | 60 | 298 | 644 | 134 | 95 | 70 |
Vassar | 4 | 7 | 60 | 4 | 7 | 60 | 345 | 745 | 191 | 125 | 90 |
Stephens | 2 | 7 | 60 | 4 | 7 | 60 | 403 | 870 | 249 | 165 | 120 |
Ramapo | 2 | 7 | 60 | 2 | 7 | 60 | 403 | 870 | 278 | 165 | 120 |
Brenau | 10 | 19 | 80 | 2 | 7 | 60 | 512 | 1106 | 387 | 215 | 160 |
Bergen | 1/0 | 19 | 80 | 1/0 | 19 | 80 | 512 | 1106 | 441 | 215 | 160 |
Converse | 2/0 | 19 | 80 | 1 | 19 | 80 | 555 | 1199 | 478 | 245 | 180 |
Hunter | 2/0 | 19 | 88 | 2/0 | 19 | 80 | 555 | 1199 | 535 | 245 | 180 |
Hollins | 3/0 | 19 | 80 | 1/0 | 19 | 80 | 603 | 1302 | 581 | 280 | 205 |
Rockland | 3/0 | 19 | 80 | 3/0 | 19 | 80 | 603 | 1302 | 651 | 280 | 205 |
Sweetbriar | 4/0 | 19 | 80 | 2/0 | 19 | 80 | 658 | 1421 | 709 | 315 | 240 |
Monmouth | 4/0 | 19 | 80 | 4/0 | 19 | 80 | 658 | 1421 | 796 | 315 | 240 |
Pratt | 250 | 37 | 95 | 3/0 | 19 | 80 | 732 | 1581 | 853 | 345 | 265 |
Wesleyan | 350 | 37 | 95 | 4/0 | 19 | 80 | 831 | 1795 | 1118 | 415 | 320 |
Holyoke | 500 | 37 | 95 | 300 | 37 | 95 | 980 | 2117 | 1545 | 495 | 395 |
Rider | 500 | 37 | 95 | 350 | 37 | 95 | 980 | 2117 | 1598 | 195 | 395 |
Code Word | Phase Conductor | Neutral | Diameter (mils) | Weight Per 1000ft (Ibs.) | Allowable Ampacities+ |
Size (AWG) | Stranding | Insul. Thick. (mils) | Size (AWG) | Stranding | Insul. Thick. (mils). | Single phase cond. | Conductor Cable |
Direct Burial | In Ducts |
QUADRUPLEX WITH YELLOW EXTRUDED STRIPE NEUTRAL |
Tulsa | 4 | 7 | 60 | 4 | 7 | 60 | 345 | 833 | 255 | 120 | 85 |
Dyke | 2 | 7 | 60 | 4 | 7 | 60 | 403 | 973 | 342 | 155 | 115 |
Wittenberg | 2 | 7 | 60 | 2 | 7 | 60 | 403 | 973 | 371 | 155 | 115 |
Notre Dame | 1/0 | 19 | 80 | 2 | 7 | 60 | 512 | 1236 | 534 | 200 | 150 |
Purdue | 1/0 | 19 | 80 | 1/0 | 19 | 80 | 512 | 1236 | 589 | 200 | 150 |
Syracuse | 2/0 | 19 | 80 | 1 | 19 | 80 | 555 | 1340 | 657 | 225 | 170 |
Lafayette | 2/0 | 19 | 80 | 2/0 | 19 | 80 | 555 | 1340 | 713 | 225 | 170 |
Swanthmore | 3/0 | 19 | 80 | 1/0 | 19 | 80 | 603 | 1456 | 798 | 250 | 195 |
Davidson | 3/0 | 19 | 80 | 3/0 | 19 | 80 | 603 | 1456 | 868 | 250 | 195 |
Wake Forest | 4/0 | 19 | 80 | 2/0 | 19 | 80 | 658 | 1588 | 974 | 290 | 225 |
Earlham | 4/0 | 19 | 80 | 4/0 | 19 | 80 | 658 | 1588 | 1062 | 290 | 225 |
Slipperyrock | 350 | 37 | 95 | 4/0 | 19 | 80 | 831 | 2006 | 1544 | 385 | 305 |