Material Shape
Round Wire
Range of Application
Mine
Certification
ISO9001, CCC
Material
Aluminium or Copper
Transport Package
Wood Drum or Steel- Wood Drum
Specification
Power Cable
Copper PVC (XLPE) Insulated PVC Sheathed Control Cable
Application range
Power and control cable for fixed installation in the following applications:
For indoor and outdoor use
Burial without additional, suitable underground protection according to VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4)
governing PVC cables for direct burial: normal minimum installation depth 0.6 m, but at least 0.8 m under roads
In concrete with a temperature below the maximum cable operating temperature of +70 °C according to the VDE standard HD
603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial
In water: no longer than 2 weeks at a time, maximum submersion depth 10 metres, only in static water/bodies of water without
shipping traffic
Product Make-up
Aluminium conductor
Abbreviations "re", "rm", "se", "sm": r = round conductor form; s = sectorial conductor form; e = single-wire conductor (wire =
conductor)/braided conductor class 1 according to IEC 60228/VDE 0295 for fixed, static applications; m = multi-wire
conductor/braided conductor class 2 according to IEC 60228/VDE 0295 for fixed, static applications, but with a slightly lower
minimum bending factor
Core insulation: Based on PVC
Filling compound over the core assembly
PVC-based outer sheath
Norm references / Approvals
HD 603/VDE 0276-603
Product features
Flame-retardant according IEC 60332-1-2
Maximum tensile strain for aluminium conductors during installation is 30 N/mm² according to HD 603/VDE 0276-603: Part 1
Appendix A.4.12 and Part 3-G point 4
Current rating according to HD 603/VDE 0276-603, Part 3-G, Table 14 (buried at +20 °C ground temperature according to HD
603/VDE 0276-603, Part 3-G, point 5) for routing underground and Table 15 (in the air at an air temperature of +30 °C
according to HD 603/VDE 0276-603, Part 3-G, point 5) when used outdoors; but always taking into consideration
corrections/reductions to the current rating that may be necessary according to VDE 0298-4, and VDE 0298-4 (also refer to the
catalogue appendix T12) for installation in and on buildings
Technical Data
Core identification code: According to VDE 0293-308 (table T9)
Classification: ETIM 5.0 Class-ID: EC000057
ETIM 5.0 Class-Description: Low voltage power cable
Conductor stranding: Single-wire
Minimum bending radius: Fixed installation: 12 x outer diameter
Nominal voltage: Uo/U: 0.6/1.0 kV
Test voltage: 4000 V
Temperature range: During installation: -5°C to +50°C
Fixed installation: -30°C to +70°C
Number of cores and mm² per conductor | Outer diameter (mm) | Alu index (kg/km) | Weight (kg/km) |
4*35re | 29 | 406 | 1170 |
4*50se | 30 | 580 | 1305 |
4*70se | 35 | 812 | 1730 |
4*95se | 9 | 1102 | 2205 |
4*120se | 2 | 1392 | 2655 |
4*150se | 46 | 1740 | 3150 |
4*185se | 51 | 2146 | 3925 |
4*240se | 60 | 2784 | 4880 |