Model NO.
LGJ-120/20 (ACSR)
Conductor Material
Aluminum
Material Shape
Round Wire
Range of Application
Aerial Power Distribution Lines
Certification
ISO9001, CE, UL, CCC, TUV
Rated Voltage
0.6/1kv DC /AC
Supplier′s Nature
Manufacturer Exporter
Cross Area(Mm)
10/2-800/100
Standard of Other Country
CSA IEC, ASTM, DIN, BS, GOST,Sas Standard.
Temperature Rating
-45°c ~ 125°c
Specification
IEC, ISO, GB, TUV, CCC
ACSR Conductor:
ACSR is a composite concentric-lay-stranded conductor. Galvanized steel strand or strands form the central core of the conductor, around which is stranded one or more layers of EC Grade Aluminum wires. The steel core may consist of a single strand or a concentric stranded cable of 7, 19, 37, or more wires. Numerous combinations of aluminum and steel strands and layers are possible.
Applications:
Conductor(AAC, AAAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
Material Standard:
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
2) The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
3) Production can be arranged according to customers requirements for material standard,etc.
Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced
Standards:
ASTM-B232 Standard specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
BS215-2 aluminum conductors steel-reinforced -For overhead power transmission
DIN48204 Steel reinforced aluminum stranded conductors
IEC209 Aluminum stranded conductor steel reinforced
Customized type available.
ACSR Technical Characteristics Based on Standard BS 215-2:
Code name | Nominal aluminum area | Stranding and wire diameter | Sectional area of aluminum | Total sectional area | Approx. overall diameter | Approx. mass | Calculated D.C. resistance at 20oC | Calculated breaking load |
Al | Steel |
mm2 | No./mm | mm2 | mm2 | mm | kg/km | Ω/km | kN |
RABBIT | 50 | 6/3.35 | 1/3.35 | 52.88 | 61.7 | 10.05 | 214 | 0.5426 | 18.35 |
DOG | 100 | 6/4.72 | 7/1.57 | 105 | 118.5 | 14.15 | 394 | 0.2733 | 32.7 |
WOLF | 150 | 30/2.59 | 7/2.59 | 158.1 | 194.9 | 18.13 | 726 | 0.1828 | 69.2 |
DINGO | 150 | 18/3.35 | 1/3.35 | 158.7 | 167.5 | 16.75 | 506 | 0.1815 | 35.7 |
LYNX | 175 | 30/2.79 | 7/2.79 | 183.4 | 226.2 | 19.53 | 842 | 0.1576 | 79.8 |
ZEBRA | 400 | 54/3.18 | 7/3.18 | 428.9 | 484.5 | 28.62 | 1621 | 0.0674 | 131.9 |