Conductor Material
Aluminum
Material Shape
Round Wire
Range of Application
Overhead, Power Transmission Line
Original Place
Henan, China
Standards
IEC61089, ASTM, DIN
Working Temperature
-20~90
Features
Power Cable Charecters and Aerial Cable
Conductor Materials
Aluminum, Aluminum Alloy
Insulation/Jacket Material
PVC/HDPE/XLPE
Delivery Detail
7~25working Days or Depends on Your Quantity
Packaging Details
Wooden Drums, Steel Drums, Steel Wooden Drums.
Specification
ASTM ANSI/ICEA S-76-474 and NFC33-209
Origin
Luoyang, Henan, China
ABC(Aerial Bundled Cable):
Standard: IEC60502, NF C33-209, GB 12527-90
Rated voltage: 0.6/1kV
Specification:
Concentric strand aluminum wires as phase conductor; AAAC(all aluminum alloy conductors) or ACSR(aluminum conductor steel reinforced) as messenger (Neutral) core; Phase conductor is insulated by XLPE or HDPE or PVC.
Application:
The cable as a new-type aerial cable is used for transmitting electric power overhead, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204.
We can also manufacture ABC cable according to customer's special requirements.
The basic construction is as follows:
3 power cores consisting of standard aluminium conductors, insulated with
XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
To be used at voltage of 600V phase-to-phase or less and at conductor temperatures not to exceed 75 centigrade for polyethylene insulated conductors or 90 centigrade for crossliked polyethylene(XLPE) insulated conductors.
It meets or exceeds the following specifications:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.
5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Duplex Service Drop
1.Application
Primarily used for 120volt overhead service application such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2.Construction
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) | Allo wable Amp acitles |
Size (A WG) | Stranding | Insul Thick(Mils) | Size (AWG) | Stranding | Rated Strength (lbs.) | inches | XLP | POLY | XLP | POLY |
AAC Neutral-messenger |
Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 10.36 | 61 | 61 | 85 | 70 |
Collie | 6 | 7 | 45 | 6 | 7 | 563 | 10.36 | 64 | 64 | 85 | 70 |
Dachshund | 4 | 1 | 45 | 4 | 7 | 881 | 10.36 | 92 | 92 | 115 | 90 |
Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 10.36 | 96 | 96 | 115 | 90 |
Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 14.88 | 147 | 147 | 150 | 120 |
Malemute | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 14.88 | 234 | 234 | 205 | 160 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun.
Triplex Service Drop
1.Application
Used to supply power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2.Construction
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) | Allo wable Amp acitles |
Size (A WG) | Stranding | Insul Thick(Mils) | Size (AWG) | Stranding | Rated Strength (lbs.) | inches | XLP | POLY | XLP | POLY |
AAC Neutral-messenger |
Pateela | 6 | 7 | 45 | 6 | 7 | 563 | 14.88 | 103 | 103 | 85 | 70 |
Oyster | 4 | 7 | 45 | 4 | 7 | 881 | 14.88 | 154 | 154 | 115 | 90 |
Clam | 2 | 7 | 45 | 2 | 7 | 1350 | 20.58 | 233 | 233 | 150 | 120 |
Murex | 1/0 | 7 | 60 | 1/0 | 7 | 1990 | 20.58 | 374 | 374 | 205 | 160 |
Purpura | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 20.58 | 368 | 368 | 205 | 160 |
Nassa | 2/0 | 7 | 60 | 2/0 | 7 | 2510 | 25.42 | 462 | 462 | 235 | 185 |
Melita | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 29.97 | 562 | 562 | 275 | 215 |
Portunus | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 29.97 | 696 | 696 | 315 | 245 |
Nannynose | 336.4 | 19 | 60 | 336.4 | 19 | 6146 | 38.79 | 1118 | 1118 | 420 | 325 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun. |
Quadruplex Service Drop
1.Application
Used to supply 3-phase power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2.Construction
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) | Allo wable Amp acitles |
Size (A WG) | Stranding | Insul Thick(Mils) | Size (AWG) | Stranding | Rated Strength (lbs.) | inches | XLP | POLY | XLP | POLY |
AAC Neutral-messenger |
Clydessdale | 4 | 1 | 45 | 4 | 7 | 881 | 20.58 | 198 | 198 | 100 | 80 |
Pinto | 4 | 7 | 45 | 4 | 7 | 881 | 20.58 | 211 | 211 | 100 | 80 |
Mustang | 2 | 7 | 45 | 2 | 7 | 1350 | 25.42 | 318 | 318 | 135 | 105 |
Criollo | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 25.42 | 503 | 503 | 180 | 140 |
Percheron | 2/0 | 11 | 60 | 2/0 | 7 | 2510 | 29.97 | 619 | 619 | 205 | 160 |
Hanovarian | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 35.18 | 764 | 764 | 235 | 185 |
Oldenburg | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 35.18 | 945 | 945 | 275 | 210 |
Lippizaner | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 38.79 | 1519 | 1519 | 370 | 280 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun. |
About Asian Sun Group
1: a group with seven sub-companies;
2: Factory about 200,081 square meters;
3: 800 staffs and 40 engineers, 11 production lines;
4: production capacity: 100,000m/day.
Our Products
Mainly Electric Cables & Wires, 300 Varieties, 2000Kinds Specifications
No. Products Name
1 electrical wires, power cables, control cables
2 solar cables
3 aerial cables
4 all aluminum conductor(AAC)
5 aluminum conductor steel reinforced wire(ACSR)
6 all aluminum alloy conductor(AAAC)
Our service
1) Inquiries are answered within 12 hours and OEM is welcome.
2) 11 production lines, experienced QC to control the quality of kinds of cables.
3) CCC Certificated, and can provide CE, RoHS and SGS certificates before exporting.
4) Grown from a small factory with annual turnover of $50,000,to over$50,000,000 during 10years.\
5) Ship your order immediately after contracted. We ship worldwide.
6) 800 staffs and 40 engineers, we all glad to provide you best service.
Welcome to contact us.
Luoyang Asian Sun Industrial Group Co.,Ltd
Tel:+86-0379-69991591
Fax:+86-379-62276331
Mobile:+86-13271534528
Web:http://www.yr-group.cn
Showroom:http://lyyari.en.alibaba.com/
Address: Eastern Industry Park, Yichuan County (Yichuan Electricity Industry zone) Luoyang City, Henan Province, China