Conductor Type
Class 5 Conductor
Conductor Material
Copper
Insulation Material
Rubber
Material Shape
Round Wire
Range of Application
Mining
Certification
ISO9001, CCC
APPLICATION
The productor is mainly applied for movable electrical equipments and coal cutter.
CABLE STANDARDS
The product is manufacturedaccording to the standards MT818
Type and name of cable
Type
Rated Voltage (KV)
Name
Application
MCP
0.66/1.14
Rubber sheathed coal cutter Non-Metallic Shielding flexible cable
For power supply of coal cutter or similar equipment of rated voltage 0.66/1.14KV
Production Range Of Cable
Type
Rated Voltage (KV)
Nominal cross-sectional area of main core(mm2)
Number of cores
Main Core
Earthing Core
Monitoring Core
MCP
0.66/1.14
35-185
3
1
3
Characteristics
1. Conductor temperature
Maximum conductor temperature in normal use: 90ºC.
2. Operating temperature
Permissible long-term operating temperature: Lowest working temeperature is -35ºC.
DIMENTIONS-MCP-0.66/1.14KV
(Flexible Coal Cutter Rubber-sheathed Cables For Mining Purposes)
Nominal cross sectional area of conductor(mm²)
Conductor Structure No.(mm)
Insulation Thickness (mm)
Sheath Thickness (mm)
Average diameter
Cable Approx.Weight (kg/km)
Max.D.C Resistance (20ºC)Ω/km
Current carring capacity(20ºC)A
Nominal (mm)
Max (mm)
3x35+1x6+3x2.5
276/0.40
2.0
6.0
47.2
51.4
3250
0.565
150
84/0.30
3.39
49/0.25
8.83
3x50+1x10+3x4
396/0.40
2.2
7.0
54.3
58.6
4600
0.393
185
84/0.40
1.95
56/0.30
5.47
3x70+1x16+3x4
360/0.50
2.2
7.0
59.6
64.3
5380
0.277
230
126/0.40
1.24
56/0.30
5.47
3x95+1x25+3x6
475/0.50
2.4
7.0
64.5
70.1
7020
0.210
280
196/0.40
0.795
84/0.30
3.60
3x120+1x25+3x6
608/0.50
2.6
7.0
66.5
74.5
8400
0.164
325
196/0.40
0.795
84/0.40
3.60
3x150+1x35+3x10
756/0.50
2.6
7.0
71.0
79.5
9750
0.132
368
276/0.40
0.565
84/0.40
2.09
3x185+1x50+3x10
925/0.50
2.6
7.0
76.0
83.0
11130
0.108
422
396/0.40
0.393
84/0.40
2.09