Model NO.
60245 IEC 81 (YH)
Conductor Type
Class 6 Conductors.
Application
Electric Welding Machine
Conductor Material
Copper
Insulation Material
Rubber
Material Shape
Round Wire
Range of Application
Electric Welding Machine
Certification
ISO9001, CE, CCC
Class of Conductor
Class 2
Rubber Sheathed Arc-welding Electrode Cable (60245 IEC 81 YH)
APPLICATION
60245 IEC81(YH) Rubber Sheathed Flexible Cable.It is suitable for connnecting welding clamp.
-----------------------------------------------------------------------------------------------------------------------------
BASIC INFORMATION
Code Name
60245 IEC 81(YH)
Rated Voltage (Uo/U)
As this type cable is intended exclusively for welding purposes no rated voltage is given.
Cable Structure
CU/Rubber Insulation(as well as sheath)
-----------------------------------------------------------------------------------------------------------------------------
CONSTRUCTION
Conductor
-Stranded Copper
Number of conductors:1
The wires may be plain or tinned
Inner Layer Separator Layer
Polyester film taping or other suitable material shall be applied around the conductor
Covering
-Rubber compound Type SE3,constituting the insulation as well as the sheath
-----------------------------------------------------------------------------------------------------------------------------
CABLE STANDARDS
IEC60245,JB/T8735,GB/T5013,BS,DIN,ICEA up on request.
-----------------------------------------------------------------------------------------------------------------------------
CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 60ºC
Ambient temperature
Permissible Min.temperature is -35ºC
The Bending Radius Of Cable(D-Diameter of cable)
D≤25mm: Radius≥4D
D>25mm: Radius≥6D
-----------------------------------------------------------------------------------------------------------------------------
DIMENSIONS-60245 IEC 81(YH)
Nominal Cross Sectional Area of Conductor(mm2) | Number of conductor | Diameter of wires in conductor(mm) | Max.Overall Diameter (mm) | Max.conductor resistance at 20ºCPlain(Ω/km) | Permissible Current Rating(A) |
10 | 322 | 0.20 | 9.7 | 1.91 | 75 |
16 | 513 | 0.20 | 11.5 | 1.16 | 105 |
25 | 798 | 0.20 | 13.0 | 0.758 | 135 |
35 | 1121 | 0.20 | 14.5 | 0.536 | 170 |
50 | 1596 | 0.20 | 17.0 | 0.379 | 215 |
70 | 2220 | 0.20 | 19.5 | 0.268 | 265 |
95 | 2997 | 0.20 | 22.0 | 0.198 | 325 |
120 | 1702 | 0.30 | 24.0 | 0.161 | 380 |
150 | 2146 | 0.30 | 27.0 | 0.129 | 435 |
185 | 1443 | 0.40 | 29.0 | 0.106 | 496 |